Troubleshooting > Troubleshooting DataConnect > Error during execution
Was this helpful?
Error during execution
 
Error Code
8, 50
Error Message
Error during execute:
Description
This error message is displayed for SMTP Email Invoker 1.1.2, the From and To component property values are not defined.
This error message is also displayed for Salesforce Bulk Loader 2.0.1 or Salesforce Login Invoker 2.0.1, when Endpoint Address is incorrect.
Cause/Solution 1
Cause: The From and To component properties are not defined.
Solution:
1. Double-click the SMTP Email Invoker.
2. Edit the component properties.
3. Define From and To values.
4. Save component properties and Run the Process.
Cause/Solution 2
Cause: The Endpoint Address is incorrect.
Solution: Change the value of Endpoint Address (component property for Salesforce Bulk Loader and step property for Salesforce Login Invoker):
1. Double-click the step.
2. Specify a valid Endpoint Address like https://www.salesforce.com/services/Soap/u/54.0. You can change the number in the URL to any supported version, including versions 21.0 to 54.0.
3. Save and Run the Process.
Related Information
Last modified date: 10/22/2024