6. Troubleshooting Ingres : Ingres Processes on UNIX : Check for Data Access Server Process on UNIX
 
Share this page                  
Check for Data Access Server Process on UNIX
The command to start the Data Access Server process (iigcd) from the installation owner login is ingstart -iigcd. If the Data Access Server did not start:
1. Verify that the recovery process (dmfrcp) is running. More information is provided in Check for Recovery Process Errors on UNIX.
2. Verify that the recovery process (see Recovery Process Monitoring) not in a recovery state. This is a likely situation if there was a sudden shutdown because of a power failure or some other systems failure.
3. Try to start up a Data Access server. Issue the following command at the operating system prompt:
ingstart -iigcd
4. If you corrected a Data Access server problem, verify that Ingres starts normally:
a. Shut down the partially started installation with the ingstop command.
b. Restart the installation with the ingstart command.