G. SunLink Gateway Configuration Files : Solaris Dependent LUs
 
Share this page                  
Solaris Dependent LUs
The following example is for Solaris dependent LUs. This file is usually in the opt/SUNWconn/snap2p/p2_etc/config directory.
:DEFINE_PU:
pu_name              = S1MVS, network_name = RTIBM
contents_id          = 01234567

:DEFINE_NODE:
pu_name              = S1MVS, node_id = NODE0

:DEFINE_LOCAL_LU:
fql_lu_name          = RTIBM.S1115001 # An LU name in VTAM/NCP gen
lu_local_address     = 1
lu_name              = S1115001       # An LU name in VTAM/NCP gen
lu_session_limit     = 1

:DEFINE_PARTNER_LU:
fql_plu_name         = RTIBM.A04IS1G2 # VTAM Applid for
                                      # Ingres
                                      # Enterprise Access
                                      # to DB2
parallel_session     = no             # Must set to this value
lu_is_dependent      = yes            # Must set to this value
initiate_type        = INITIATE_ONLY
security_acceptance  = NONE

:DEFINE_MODE:
mode_name            = INGLU62
unique_session_name  = s1             # This is the name specified
                                      # as the Node Address in
                                      # NETU entries
snd_pac_window       = 0              # Recommended
rcv_pac_window       = 0              # Recommended
snd_max_ru_size      = 4096           # Recommended
rcv_max_ru_size      = 4096           # Recommended
sync_level           = none
sess_reinit          = INIT_PLU_OR_SLU
auto_activate_limit  0
session_limit        = 1              # Must set to this value
min_conwinner_limit  = 1
min_conloser_limit   = 0
The following example is for an SDLC connection through the serial port:
:DEFINE_DLC:
dlc_name              = XLINK000
device_driver_name    = /dev/sdlc
port_driver_name      = zsh0
dlc_type              = sdlc
npr_timeout           = 240
pause_timeout         = 2
idle_timeout          = 1400        # for maxdata = 1033
                                    # & line speed = 9600
maxdata               = 1033        # [frm_size - 8]
retries               = 32
window_size           = 7
sdlc_addr             = 0x1
full_duplex           = yes
nrzi                  = no
multipoint            = yes
switched_line         = no
block_number          = 056         # MUST be first of xid
                                    # parameters
id_number             = E2E43
role                  = secondary
tx_rx_capability      = simultaneous
max_rcv_iframe_size   = 7
include_control_point = yes         # xid control vector
include_link_station_name  = yes    # xid control vector

:DEFINE_ALS:
dlc_name              = XLINK000
pu_name               = S1MVS
als_name              = XXALS000