Bridge Server Errors on VMS
The Bridge Server process (II_GCB_nnn, where the nnn is a number related to the server’s process ID) does not start if the following errors occur:
• The II_CONFIG:errlog.log file has a notation regarding the failure of the Bridge Server process.
• The show system command does not list a II_GCB_nnn process.
• The utility iinamu does not display a process name when you enter the show bridge command at the IINAMU> prompt.
Check for Bridge Server Process Errors on VMS
If Bridge Server does not start, follow these steps:
1. Verify that you have installed the Ingres Net component.
2. Verify that you have installed the correct protocol drivers and they are functioning properly.
3. Verify the Bridge Server has been properly configured using the Configuration-By-Forms (cbf) utility. If you are still having problems, set the following trace to capture additional diagnostic data before calling technical support:
define II_GC_TRACE 4
define II_GC_LOG filename
ingstart -iigcb
Last modified date: 01/30/2023