Release Summary > Change Log
Was this helpful?
Change Log
Change Log for 12.3 (Build Number 12.3.0-43)
The following table provides information about the bug fixes and specific customer requests addressed in the Actian DataConnect 12.3.0-43 release. Later releases automatically include the change.
Bug ID
Description
Resolution
DCNG-27158
When a batch script is selected for the command line option in the Application step, the process hangs instead of pausing and opening a terminal window.
Fixed
DCNG-27155
The Script step execution time is exceedingly long when used with the StrReplace function.
Fixed
DCNG-27007
When using the JDBC source connector to read a PostgresSQL database, the Automatic Mapping Transformer version 2.0.1 component fails.
Fixed
DCNG-27006
Left and Right EZscript functions configured in a map execute on strings with null values in v12.0 but fail in v12.3.
Fixed
DCNG-27004
Multiple executions of the Automatic Mapping Transformer component leaves connections open when Clear Mapped Schema is enabled.
Fixed
DCNG-27001
The Automatic Mapping Transformer component returns Error 15 when executed on Windows 10 using the Salesforce source connector.
Fixed
DCNG-26999
When the Automatic Mapping Transformer component has the Auto Map Method property set to Recommended or Relative, the following error is returned during process execution:
Error during execute: Closing command object: Exception in batch execute: Packed Decimal overflow detected in query.
Fixed
DCNG-26991
During process execution, scripts using DJExport fail to write to an Actian Warehouse table.
Fixed
DCNG-26979
On Windows, process execution fails when using the JDBC source and target connector and the Automatic Mapping Transformer component to read a Microsoft SQL Server 2019 database and write to an Actian Data Platform warehouse.
Fixed
DCNG-26974
When defining a map using the Actian Warehouse connector and the Actian Ingres (ODBC 3.x) connector, the following error is returned:
Error 19 connecting to 'Actian Warehouse': From Connect (driver): SQL state IM003, message:
Specified driver could not be loaded due to system error 182: (Actian, C:\Program Files\Actian\Actian Client AC\ingres\bin\caiiod35.dll).
Fixed
DCNG-26971
A process which contains a Transformation step fails when the map path for the Transformation step specifies multiple local macros.
Fixed
DCNG-26960
On Windows 10, when the Automatic Mapping Transformer component uses the OCBC 3.5 target connector an additional, invalid output mode is displayed.
Fixed
DCNG-26954
When a user changes the password for the source or target connector being used in a map, references to the password are not updated properly in the .map.rtc JSON source file. This occurs whether the user changes the password from clear text to a macro, or from a macro to a clear text.
Fixed
DCNG-26952
The value of the map connector DriverOptions property set by the user gets cleared when the data source changes.
Fixed
DCNG-26949
The following error is returned when deleting a log file for a process created using the process wizard:
An exception has been caught while processing the refactoring ‘Delete Resource’.
Reason:
Problems encountered while deleting resources.
Fixed
DCNG-26947
In the process wizard, when using the Actian Warehouse target connector the following error is returned when the user manually enters the DriverOptions property (rather than selecting an option from the drop-down menu):
errorCodeFrom Connect (driver): SQL state 08004, message:
[Actian][Actian AC ODBC Driver][INGRES]A server class was provided as part of the database name (dbname/class), but no server has registered the requested server class.
Fixed
DCNG-26945
In the process wizard, when using the Actian Warehouse source connector the following error is returned when the user manually enters the DriverOptions property (rather than selecting an option from the drop-down menu):
From Connect (driver): SQL state 08004, message:
[Actian][Actian AC ODBC Driver][INGRES]A server class was provided as part of the database name (dbname/class), but no server has registered the requested server class.
Fixed
DCNG-26930
In DataConnect Studio, when creating a process which contains a Transformation step, and the map location path to that Transformation step is a local macro, either the value for local macro disappears or the process errors out when the Map step is deselected.
Fixed
DCNG-26928
When connecting to the Salesforce source connector on Windows 10, the following schema mismatch error is returned if a process contains an Automatic Mapping Transformer step that is used against multiple tables:
Error 15: B_BADMATCH occurs when engine tries to resolveSchemas()
Fixed
DCNG-26926
In DataConnect Studio, when executing a map which uses an XML data source, the following error is returned:
Execution ended in error--> Unable to process control schema: Cannot deserialize value of type `com.pervasive.di.artifacts.schema.ExternalProperties$SignStyle` from String "SEPARATE": not one of the values accepted for Enum class: [ACUCOBOL, WANG, IBM, RMCOBOL, PARENS, MFCOBOL, UNISYS, DB, CR, MINUS, ANGLE]
 at [Source: REDACTED (`StreamReadFeature.INCLUDE_SOURCE_IN_LOCATION` disabled); line: 251, column: 33] (through reference chain: com.pervasive.di.artifacts.schema.JsonSchema["schema"]->com.pervasive.di.artifacts.schema.Schema["type_defs"]->java.util.ArrayList[0]->com.pervasive.di.artifacts.schema.TypeDef["groups"]->java.util.ArrayList[0]->com.pervasive.di.artifacts.schema.Group["sequence"]->java.util.ArrayList[24]->com.pervasive.di.artifacts.schema.Field["external"]->com.pervasive.di.artifacts.schema.ExternalProperties["sign_style"]). Check log for more details
Fixed
DCNG-26915
When creating a process on Windows 2022 Data Center with Desktop Experience, DataConnect Studio closes due to an issue with ZLIB.DLL.
Fixed
DCNG-26914
On Windows 10, processes which contain the Salesforce Changed Data Query Invoker step fail to execute and return the following error:
07/30/2024 15:10:15 4 19 M SalesforceChangedDataQueryInvoker org.apache.axiom.core.stream.StreamException: javax.xml.stream.XMLStreamException: DOCTYPE is not allowed
07/30/2024 15:10:15 1 0 M SalesforceChangedDataQueryInvoker
The serverURL and/or sessionId were not specified. Using UserName and Password properties to login.
07/30/2024 15:10:15 4 19 O Global Error during execute: org.apache.axiom.core.stream.StreamException: javax.xml.stream.XMLStreamException: DOCTYPE is not allowed
07/30/2024 15:10:15 1 19 O Global *** Invoker Step End: [Invoker_1] failed.
Fixed
DCNG-26913
When using the HIPAA (eDoc) or EDI X12 (eDoc) source connectors in a map, no values are returned if a repeating field which contains a delimited string is mapped to an array for conversion.
Fixed
DCNG-26910
When multiple global macros are defined for different maps in a process, only a single macro executes on the maps.
Fixed
DCNG-26823
The HCL OneDB Multimode connector does not correctly write data into CLOB datatype fields.
Fixed
Last modified date: 12/03/2024